Note: Calibration settings of panning, tilting, and zooming will be maintained even after all reset. Turn on the power while holding down the buttons 2, 4, and 6. Enter the administrator password. If the password entered is correct, all the settings will be reset to the factory default.
This setting is required to establish a connection between the system units and system controller. Welcome to ManualMachine. We have sent a verification link to to complete your registration.
Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Model No. Serial No. SA 13 Unplug this apparatus during lightning storms or when unused for long periods of time. Switch Setting To prevent electric shock, do not remove screws or covers.
Do not strike or shake, as this may damage the appliance. The input power source for this appliance is V AC, 50 Hz. Term Examples of Model Nos. Remarks on Model Nos. This is the illustration of WV-CU Note: Refer to p. Rst F1 F2 F3 F4.
Controller No. Combination code label has been stuck on the bottom. Cable supplied. Combination Fit the cable code label into the cable trench. Set the MODE switches. If using two or more system controllers in daisy chain connections Up to 4 system controllers are connectable in the system. Turn off the power. AllAllResetReset 5. All Reset End 6. You can only view or download manuals with. Sign Up and get 5 for free.
Upload your files to the site. You get 1 for each file you add. The error occurs when you specify a device that cannot be used by FP0 e. Check the device setting details of the registered parts and change them to devices that can be used by FP0. GT Can I switch screens by using both the function switch and programmable controller?
You can switch the screens using the function switch by directly designating a screen number regardless of the controller status. You can also switch the screens from the controller by writing the screen number data in DT0. However, if you use both methods, there will be a difference between the screen switching data in DT0 and the currently displayed screen data in DT2, and screen switching by the controller may be impossible.
In such cases, set the screen switching data in DT0, and then set and reset the forced screen switching flag internal relay RE. May I uninstall it since it is no longer necessary? Yes, you can uninstall it. But make sure to leave the shared files installed during the uninstallation operation. Go to Start, Run, type this file name, and press OK to uninstall the previous version.
Regarding FP-e, I need to prevent the current screen from jumping to another even when the mode switch is pressed. For example, when I want to use only normal screen 1, what setting is required? Execute the screen display switching instruction F using R always-ON relay in order to keep the designated screen always displayed.
Even when I directly monitor the terminals, no changes were found. For details, refer to the Programming Manual. Which instruction should I use to convert BCD data to decimal numbers for comparison? Use the F81 instruction for conversion of four-digit BCD into decimal numbers 16 bits.
Use the F83 instruction for conversion of eight-digit BCD into decimals 32 bits. The comparison instructions apply to comparisons between decimal numbers, Use the F60 instruction for bit decimal numbers, and F61 for bit decimal numbers.
The system register counter number of FP2 starts from by default. Set the counter starting address to by editing the system register PLC configuration in order to enter CT Not available with FP0. How do I restore it? The counter number of FP2SH starts from by default. Set the counter starting address to by editing the system register PLC configuration.
However, the supplied cable cannot be used. I need to order the wire-press connector separately. What is the part number? GT30 cannot communicate with a notebook PC. FP2 can communicate with it. Since the output of the FP2 positioning unit is an open collector, how do I connect them? What hardware is required to connect FP3 to my PC for program maintenance? Also, what hardware is required to connect the data processing unit? Since I forgot my password, I forcibly released the protection.
Then the PC froze. When the forced password release is executed, the completion can take a maximum of one hour to complete. However, this does not mean that the PC will freeze. Please activate another application from the Start menu or the task bar, and you will be able to see that it can operate.
Moreover, how should be carried out to write a Hex value to the Initial portion of variable registration? It will become a compile error if H is described. In the case of a hexadecimal number, a data type is set as WORD, and the input of an initial value attaches 16 to a numerical head. For example, H inputs 16 It will become a compile error if a Global variable is specified and registered into D-Word types data relation for motor control, acceleration, etc.
Although it seems that there is also quite little area of R when assigning an internal relay to switches and lamps, such as a touch panel, and registering an internal relay into a global variable, is there any method of expanding?
In order to make it hold area, please build in the battery of FPsigma first. It is set as 0 to make it all-points holdding. In addition, in case a program is rewritten, in order not to initialize the value of hold area, please be sure to put a check mark into "Retain variables in the user area notinitialized" in the code generation of a compile option.
Since you can change the range of user area of the internal relay R like DT. The point of contact of Y? The maximum number of editable lines is the maximum number of program lines that can be converted in Ladder Symbol View LDS editing mode. When this limit 33 lines is exceeded, the error occurs.
Delete the excess lines. It is impossible to automatically hold the data of all registers. Don't execute it by using R always ON.
Note that the F-ROM writing is limited to approx. Is there a remedy? The program was deleted or crashed due to battery backup failure of the built-in RAM battery. Please enter the program again. Basically, it is not supported although some functions can be used. But they did not communicate. FP2 can use up to two ports computer communication function simultaneously. Must a common power supply be used as the external power supply of the FP2 point NPN transistor output type and the power supply of the loads?
Can Y0 and Y1 be used at different voltages? There are no problems with the use of separate power supplies. If a common negative line is used, every load can use a different power supply. Will there be a problem? The quantities depend on the unit type. How do I arrange the data in "Edit Data Register" into a single column? Set the number of columns to 1. Can this accessory combination also be used for any other PLC? You need a commercially available straight cable 25 pins - 9 pins. Which tool is required for programming FP1?
Is this all right? This is caused since the instruction handling real numbers cannot display integers. Please rest assured that this is not abnormal. What will happen if the single frame command is executed during multiple frame processing by the multiple frame command of MEWTOCOL without aborting processing? There are no differences. They can be used in the same manner. Please note that when using index modification in units of 32 bits, designation of IX automatically sets the high 16 bits to IY.
What are the possible causes? If the cause is noise, power off and then on, and operation will be possible. If not, another possible cause is battery exhaustion.
Since battery exhaustion may damage the program, write the saved program again after battery replacement. The problem did not occur with the previous PC.
Regarding FP2, will there be any problems if the sequence program area size is set to the maximum, and FL file register is eliminated? There are no problems unless the program uses FL. When the program is 2 K, the number of program steps is 1,, and FL is 14, words, and you can change the user memory allocation to the program and FL in increments of 2 K words 2, words.
Which wire should be used for the connector? If you need a flat cable connector, use AXM with a strain relief. The wire to be used is AWG 22 or Comments not uploaded. This message appears when the optional memory for comments is not embedded in FP2. If you need to write comments in the FP2 unit, purchase the optional memory for comments. Why can data be received only once? Although data is transmitted every time the F instruction is executed, it cannot be received unless the receive buffer is cleared.
To solve this, execute the F instruction with zero transmission bytes after data is read from the buffer when the receive completion flag R is turned on. This step clears the receive buffer and turns off R, and the next data receiving will be possible. When setting it to 0, compile can be completed. The memory address range comprises the global variable part user area and the local variable part system area. The global part is common among all Panasonic PLCs where users can directly designate a value.
If you enter an invalid value in this area by using the compile option, the compile error occurs. We recommend that you use the default value. Refer to the attachment. Second and third units can also be connected. The catalog indicates that memory backup battery AFC is equivalent to CR, which is commercially available. CR is a generic name. The size is 24 mm dia. Although it is commercially available, it is classified in a special category. Therefore, you can find it in battery-specialty stores only.
I need to purchase the wire-press socket for FP0. What are the individual part numbers? The individual part numbers are as follows. With this software, you can easily upload and store the data. Batch writing in PLC is also available. The entered parameter as the home position return method is probably other than 0, 1, or 2. With regard to the E type, the setting cannot be enabled by just writing it in the shared memory. It can be enabled only after it is transferred to the system memory.
There are two methods of transferring the setting to the system memory: 1 Command transfer, and 2 Flag relay writing. The parameters will be transferred to the system memory.
The data will be transferred to the system memory. The setting cannot be enabled without the program for transferring data to the system memory with either method. Check if the transfer program is written. For CH2, what should be written? Use the setting data register SV. The timer number and the SV number match. When powered off, all SV values become zero. Therefore, insert the initial value setting program at the top of the program by using initial pulse relay R What is the deviation counter clear output of Y2?
It is a relay that outputs an external signal at the same time the pulse output stops after the home position return is completed. Connect the contact to the deviation counter clear input of the motor driver to execute the deviation counter clear.
It is a ROM writing error. Please check for the above causes. In addition, he has also assigned the transmitting buffer and receiving buffer every words, and is trying not to generate overflow. The transmission size in one packet of Transparent communication is a maximum of words. Then, since transceiver processing of the data for words was carried out by one packet, it cannot communicate normally.
As a solution, I divide into words and ask you to have you transmit and receive. In addition, I can use a transceiver buffer for words in that case, setting it up. Transparent communication needs to carry out the communications processing of the communication data by 1 packet within the limits of the Ethernet frame. I need to use VBA to customize the Excel screen. There are two methods. The calendar will be corrected at 0 minutes and 0 seconds.
The other is to write H1 in DT for a second correction 0 to 29 sec: round down, 30 to 59 sec: round up. The FP2 pulse output unit can move three axes separately.
However, it can only move the last axis written in the program for moving all axes. Why does this happen? To move all three axes, set each axis operation at once, for example, FFFFF in shared memory addresses h and h. When the Enable signal and then the Start signal are turned on, the pulses will be generated simultaneously. What will happen when the transmission byte size for the serial communication instruction F is set to a negative value? When the transmission byte size is seven bytes, does the transmission data table need four words?
When will the receive buffer be cleared? When setting the transmission byte size to a negative value, the data will be transmitted without an end code. When the transmission byte size is seven bytes, the transmission data table needs four words, but the eighth byte data will not be transmitted.
The receive buffer will be cleared when the F instruction is executed. According to the information, the large capacity capacitor of the FP1 C14 and C16 data memory can back up data for ten days. How long does it take to charge? Is this possible?
Receiving is impossible because the receive buffer is full or because the receive completion flag stays on. To solve this problem, clear the receive buffer. Specifically, execute F instruction with zero transmission bytes.
This step clears the receive buffer without transmission and turns off the receive completion flag. How do I read approx. It allows reading and writing of FL data at once, and its export function allows the data to be saved in Excel format CSV form. How do I solve this problem? Connect RS devices with 2 contacts. Figure 5. RS pinout half duplex Connect RS devices with 4 contacts.
Figure 6. RS full duplex pinout The RS employs a set of Ohm termination resistors located at each end of the line. RS Technical Specifications A description of the RS technical specifications is provided in the following table. Get a download link for your desktop Submit your email address to get a link for quick download on your desktop and get started!
The download link was sent to you, check your email. Latest version. Latest version: v Category: Serial Port Software. Demo Limitations. Demo Limitations: day fully-functional trial. Languages: English. Upgrade Discount. Setting data and production result data can be written and saved by the P13 instruction, and read out by the F12 instruction when necessary. Programs can be changed without stopping a running production line. Asia-Pacific Middle East. Application Search. Fiber Sensors Search by Specifications.
FA Technical Support. Just add on to your current system. Let's start IoT! Search Keyword. Partly Order Discontinued September 30, Basic Information.